0. Observation
Definition

This profile defines how to represent Blood Pressure observations in FHIR using a standard LOINC code and UCUM units of measure. This is a grouping structure. It has no value in Observation.valueQuantity but contains at least one component (systolic and/or diastolic).


Measurements and simple assertions made about a patient, device or other subject.

ShortFHIR Blood Pressure ProfileMeasurements and simple assertions
Comments

Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.

Control0..*
Is Modifierfalse
Summaryfalse
Alternate NamesVital Signs, Measurement, Results, Tests
Invariantsdom-2: If the resource is contained in another resource, it SHALL NOT contain nested Resources (contained.contained.empty())
dom-3: If the resource is contained in another resource, it SHALL be referred to from elsewhere in the resource or SHALL refer to the containing resource (contained.where((('#'+id in (%resource.descendants().reference | %resource.descendants().as(canonical) | %resource.descendants().as(uri) | %resource.descendants().as(url))) or descendants().where(reference = '#').exists() or descendants().where(as(canonical) = '#').exists() or descendants().where(as(canonical) = '#').exists()).not()).trace('unmatched', id).empty())
dom-4: If a resource is contained in another resource, it SHALL NOT have a meta.versionId or a meta.lastUpdated (contained.meta.versionId.empty() and contained.meta.lastUpdated.empty())
dom-5: If a resource is contained in another resource, it SHALL NOT have a security label (contained.meta.security.empty())
dom-6: A resource should have narrative for robust management (text.`div`.exists())
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
vs-2: If there is no component or hasMember element then either a value[x] or a data absent reason must be present. ((component.empty() and hasMember.empty()) implies (dataAbsentReason.exists() or value.exists()))
obs-6: dataAbsentReason SHALL only be present if Observation.value[x] is not present (dataAbsentReason.empty() or value.empty())
obs-7: If Observation.code is the same as an Observation.component.code then the value element associated with the code SHALL NOT be present (value.empty() or component.code.where(coding.intersect(%resource.code.coding).exists()).empty())
2. Observation.implicitRules
Definition

A reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc.

ShortA set of rules under which this content was created
Comments

Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.

Control0..1
Typeuri
Is Modifiertrue because This element is labeled as a modifier because the implicit rules may provide additional knowledge about the resource that modifies it's meaning or interpretation
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Summarytrue
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
4. Observation.extension:supportingInfo
Slice NamesupportingInfo
Definition

Other resources from the patient record that may be relevant to the event. The information from these resources was either used to create the instance or is provided to help with its interpretation. This extension should not be used if more specific inline elements or extensions are available. For example, use Observation.hasMember instead of supportingInformation for representing the members of an Observation panel.

ShortOther information that may be relevant to this event.
Control0..1
TypeExtension(Supporting info) (Extension Type: Reference(Resource))
Is Modifierfalse
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
ele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
6. Observation.modifierExtension
Definition

May be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

ShortExtensions that cannot be ignored
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

Control0..*
TypeExtension
Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the resource that contains them
Summaryfalse
Requirements

Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

Alternate Namesextensions, user content
Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
8. Observation.status
Definition

The status of the result value.

Shortregistered | preliminary | final | amended +
Comments

This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid.

Control1..1
BindingThe codes SHALL be taken from ObservationStatushttp://hl7.org/fhir/ValueSet/observation-status|4.0.1
(required to http://hl7.org/fhir/ValueSet/observation-status|4.0.1)
Typecode
Is Modifiertrue because This element is labeled as a modifier because it is a status element that contains status entered-in-error which means that the resource should not be treated as valid
Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
Must Supporttrue
Summarytrue
Requirements

Need to track the status of individual results. Some results are finalized before the whole report is finalized.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
10. Observation.category
Definition

A code that classifies the general type of observation being made.

ShortClassification of type of observation
Comments

In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

Control10..*
BindingThe codes SHOULD be taken from ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category
(preferred to http://hl7.org/fhir/ValueSet/observation-category)

Codes for high level observation categories.

TypeCodeableConcept
Is Modifierfalse
Must Supporttrue
Summaryfalse
Requirements

Used for filtering what observations are retrieved and displayed.

Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
SlicingThis element introduces a set of slices on Observation.category. The slices areUnordered and Open, and can be differentiated using the following discriminators:
  • value @ coding.code
  • value @ coding.system
  • 12. Observation.category:VSCat
    Slice NameVSCat
    Definition

    A code that classifies the general type of observation being made.

    ShortClassification of type of observation
    Comments

    In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set.

    Control10..1*
    BindingThe codes SHOULD be taken from ObservationCategoryCodeshttp://hl7.org/fhir/ValueSet/observation-category
    (preferred to http://hl7.org/fhir/ValueSet/observation-category)

    Codes for high level observation categories.

    TypeCodeableConcept
    Is Modifierfalse
    Must Supporttrue
    Summaryfalse
    Requirements

    Used for filtering what observations are retrieved and displayed.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    14. Observation.category:VSCat.coding
    Definition

    A reference to a code defined by a terminology system.

    ShortCode defined by a terminology system
    Comments

    Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

    Control10..*
    TypeCoding
    Is Modifierfalse
    Must Supporttrue
    Summarytrue
    Requirements

    Allows for alternative encodings within a code system, and translations to other code systems.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    16. Observation.category:VSCat.coding.system
    Definition

    The identification of the code system that defines the meaning of the symbol in the code.

    ShortIdentity of the terminology system
    Comments

    The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.

    Control10..1
    Typeuri
    Is Modifierfalse
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Summarytrue
    Requirements

    Need to be unambiguous about the source of the definition of the symbol.

    Fixed Valuehttp://terminology.hl7.org/CodeSystem/observation-category
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    18. Observation.category:VSCat.coding.code
    Definition

    A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

    ShortSymbol in syntax defined by the system
    Control10..1
    Typecode
    Is Modifierfalse
    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
    Must Supporttrue
    Summarytrue
    Requirements

    Need to refer to a particular code in the system.

    Fixed Valuevital-signs
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    20. Observation.code
    Definition

    Blood Pressure.


    Describes what was observed. Sometimes this is called the observation "name".

    ShortBlood PressureType of observation (code / type)
    Comments

    additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.


    All code-value and, if present, component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

    Control1..1
    BindingUnless not suitable, these codes SHALL be taken from For example codes, see VitalSignshttp://hl7.org/fhir/ValueSet/observation-codes
    (extensible to http://hl7.org/fhir/ValueSet/observation-vitalsignresult)

    This identifies the vital sign result type.


    Codes identifying names of simple observations.

    TypeCodeableConcept
    Is Modifierfalse
    Must Supporttrue
    Summarytrue
    Requirements
    1. SHALL contain exactly one [1..1] code, where the @code SHOULD be selected from ValueSet HITSP Vital Sign Result Type 2.16.840.1.113883.3.88.12.80.62 DYNAMIC (CONF:7301).

    Knowing what kind of observation is being made is essential to understanding the observation.

    Alternate NamesName, Test
    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    22. Observation.code.coding
    Definition

    A reference to a code defined by a terminology system.

    ShortCode defined by a terminology system
    Comments

    Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

    Control10..*
    TypeCoding
    Is Modifierfalse
    Summarytrue
    Requirements

    Allows for alternative encodings within a code system, and translations to other code systems.

    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
    SlicingThis element introduces a set of slices on Observation.code.coding. The slices areUnordered and Open, and can be differentiated using the following discriminators:
    • value @ code
    • value @ system
    • 24. Observation.code.coding:BPCode
      Slice NameBPCode
      Definition

      A reference to a code defined by a terminology system.

      ShortCode defined by a terminology system
      Comments

      Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

      Control10..1*
      TypeCoding
      Is Modifierfalse
      Summarytrue
      Requirements

      Allows for alternative encodings within a code system, and translations to other code systems.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      26. Observation.code.coding:BPCode.system
      Definition

      The identification of the code system that defines the meaning of the symbol in the code.

      ShortIdentity of the terminology system
      Comments

      The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.

      Control10..1
      Typeuri
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Requirements

      Need to be unambiguous about the source of the definition of the symbol.

      Fixed Valuehttp://loinc.org
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      28. Observation.code.coding:BPCode.code
      Definition

      A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

      ShortSymbol in syntax defined by the system
      Control10..1
      Typecode
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Summarytrue
      Requirements

      Need to refer to a particular code in the system.

      Fixed Value85354-9
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      30. Observation.subject
      Definition

      The patient, or group of patients, location, or device this observation is about and into whose record the observation is placed. If the actual focus of the observation is different from the subject (or a sample of, part, or region of the subject), the focus element or the code itself specifies the actual focus of the observation.

      ShortL'observation concerne la personne que l'on analyse.Who and/or what the observation is about
      Comments

      One would expect this element to be a cardinality of 1..1. The only circumstance in which the subject can be missing is when the observation is made by a device that does not know the patient. In this case, the observation SHALL be matched to a patient through some context/channel matching technique, and at this point, the observation should be updated.

      Control10..1
      TypeReference(Patient, Patient, Group, Device, Location)
      Is Modifierfalse
      Must Supporttrue
      Summarytrue
      Requirements

      Observations have no value if you don't know who or what they're about.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      32. Observation.effective[x]
      Definition

      Often just a dateTime for Vital Signs


      The time or time-period the observed value is asserted as being true. For biological subjects - e.g. human patients - this is usually called the "physiologically relevant time". This is usually either the time of the procedure or of specimen collection, but very often the source of the date/time is not known, only the date/time itself.

      ShortOften just a dateTime for Vital SignsClinically relevant time/time-period for observation
      Comments

      At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.


      At least a date should be present unless this observation is a historical report. For recording imprecise or "fuzzy" times (For example, a blood glucose measurement taken "after breakfast") use the Timing datatype which allow the measurement to be tied to regular life events.

      Control10..1
      This element is affected by the following invariants: vs-1
      TypeChoice of: dateTime, Period, Timing, instant
      [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
      Is Modifierfalse
      Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
      Must Supporttrue
      Must Support TypesNo must-support rules about the choice of types/profiles
      Summarytrue
      Requirements

      Knowing when an observation was deemed true is important to its relevance as well as determining trends.

      Alternate NamesOccurrence
      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      vs-1: if Observation.effective[x] is dateTime and has a value then that value shall be precise to the day ($this is dateTime implies $this.toString().length() >= 10)
      34. Observation.value[x]
      Definition

      Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.


      The information determined as a result of making the observation, if the information has a simple value.

      ShortVital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.Actual result
      Comments

      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


      An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

      Control0..01
      This element is affected by the following invariants: obs-7, vs-2
      TypeQuantity, dateTime, boolean, string, SampledData, Period, Ratio, integer, time, Range, CodeableConcept
      Is Modifierfalse
      Must Supporttrue
      Summarytrue
      Requirements
      1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

      An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

      Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
      SlicingThis element introduces a set of slices on Observation.value[x]. The slices areUnordered and Closed, and can be differentiated using the following discriminators:
      • type @ $this
      • 36. Observation.value[x]:valueQuantity
        Slice NamevalueQuantity
        Definition

        Vital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.


        The information determined as a result of making the observation, if the information has a simple value.

        ShortVital Signs value are recorded using the Quantity data type. For supporting observations such as Cuff size could use other datatypes such as CodeableConcept.Actual result
        Comments

        An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


        An observation may have; 1) a single value here, 2) both a value and a set of related or component values, or 3) only a set of related or component values. If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

        Control0..01
        This element is affected by the following invariants: obs-7, vs-2
        TypeQuantity, dateTime, boolean, string, SampledData, Period, Ratio, integer, time, Range, CodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summarytrue
        Requirements
        1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

        An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        38. Observation.dataAbsentReason
        Definition

        Provides a reason why the expected value in the element Observation.value[x] is missing.

        ShortWhy the result is missing
        Comments

        Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory".

        The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values.

        Control0..1
        This element is affected by the following invariants: obs-6, vs-2
        BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
        (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

        Codes specifying why the result (Observation.value[x]) is missing.

        TypeCodeableConcept
        Is Modifierfalse
        Must Supporttrue
        Summaryfalse
        Requirements

        For many results it is necessary to handle exceptional values in measurements.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        40. Observation.component
        Definition

        Used when reporting systolic and diastolic blood pressure.


        Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

        ShortUsed when reporting systolic and diastolic blood pressure.Component results
        Comments

        For a discussion on the ways Observations can be assembled in groups together see Notes below.


        For a discussion on the ways Observations can be assembled in groups together see Notes below.

        Control20..*
        TypeBackboneElement
        Is Modifierfalse
        Must Supporttrue
        Summarytrue
        Requirements

        Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

        Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
        vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
        SlicingThis element introduces a set of slices on Observation.component. The slices areUnordered and Open, and can be differentiated using the following discriminators:
        • value @ code.coding.code
        • value @ code.coding.system
        • 42. Observation.component.modifierExtension
          Definition

          May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

          Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

          ShortExtensions that cannot be ignored even if unrecognized
          Comments

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Control0..*
          TypeExtension
          Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
          Summarytrue
          Requirements

          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

          Alternate Namesextensions, user content, modifiers
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          44. Observation.component.code
          Definition

          Describes what was observed. Sometimes this is called the observation "code".

          ShortType of component observation (code / type)
          Comments

          All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

          Control1..1
          BindingUnless not suitable, these codes SHALL be taken from For example codes, see VitalSignshttp://hl7.org/fhir/ValueSet/observation-codes
          (extensible to http://hl7.org/fhir/ValueSet/observation-vitalsignresult)

          This identifies the vital sign result type.


          Codes identifying names of simple observations.

          TypeCodeableConcept
          Is Modifierfalse
          Must Supporttrue
          Summarytrue
          Requirements

          Knowing what kind of observation is being made is essential to understanding the observation.

          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          46. Observation.component.value[x]
          Definition

          Vital Sign Value recorded with UCUM.


          The information determined as a result of making the observation, if the information has a simple value.

          ShortVital Sign Value recorded with UCUMActual component result
          Comments

          Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


          Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

          Control0..1
          This element is affected by the following invariants: vs-3
          BindingUnless not suitable, these codes SHALL be taken from For codes, see VitalSignsUnits
          (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

          Common UCUM units for recording Vital Signs.

          TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
          [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
          Is Modifierfalse
          Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
          Must Supporttrue
          Must Support TypesNo must-support rules about the choice of types/profiles
          Summarytrue
          Requirements
          1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

          An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          48. Observation.component.dataAbsentReason
          Definition

          Provides a reason why the expected value in the element Observation.component.value[x] is missing.

          ShortWhy the component result is missing
          Comments

          "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

          The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

          Control0..1
          This element is affected by the following invariants: obs-6, vs-3
          BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
          (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

          Codes specifying why the result (Observation.value[x]) is missing.

          TypeCodeableConcept
          Is Modifierfalse
          Must Supporttrue
          Summaryfalse
          Requirements

          For many results it is necessary to handle exceptional values in measurements.

          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          50. Observation.component:SystolicBP
          Slice NameSystolicBP
          Definition

          Used when reporting systolic and diastolic blood pressure.


          Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

          ShortUsed when reporting systolic and diastolic blood pressure.Component results
          Comments

          For a discussion on the ways Observations can be assembled in groups together see Notes below.


          For a discussion on the ways Observations can be assembled in groups together see Notes below.

          Control10..1*
          TypeBackboneElement
          Is Modifierfalse
          Must Supporttrue
          Summarytrue
          Requirements

          Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
          52. Observation.component:SystolicBP.modifierExtension
          Definition

          May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

          Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

          ShortExtensions that cannot be ignored even if unrecognized
          Comments

          There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

          Control0..*
          TypeExtension
          Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
          Summarytrue
          Requirements

          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


          Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

          Alternate Namesextensions, user content, modifiers
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
          54. Observation.component:SystolicBP.code
          Definition

          Describes what was observed. Sometimes this is called the observation "code".

          ShortType of component observation (code / type)
          Comments

          additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.


          All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

          Control1..1
          BindingUnless not suitable, these codes SHALL be taken from For example codes, see VitalSignshttp://hl7.org/fhir/ValueSet/observation-codes
          (extensible to http://hl7.org/fhir/ValueSet/observation-vitalsignresult)

          This identifies the vital sign result type.


          Codes identifying names of simple observations.

          TypeCodeableConcept
          Is Modifierfalse
          Must Supporttrue
          Summarytrue
          Requirements

          Knowing what kind of observation is being made is essential to understanding the observation.

          Alternate NamesComponent Test, Component Name
          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          56. Observation.component:SystolicBP.code.coding
          Definition

          Systolic Blood Pressure.


          A reference to a code defined by a terminology system.

          ShortSystolic Blood PressureCode defined by a terminology system
          Comments

          Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

          Control10..*
          TypeCoding
          Is Modifierfalse
          Summarytrue
          Requirements

          Allows for alternative encodings within a code system, and translations to other code systems.

          Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
          SlicingThis element introduces a set of slices on Observation.component.code.coding. The slices areUnordered and Open, and can be differentiated using the following discriminators:
          • value @ code
          • value @ system
          • 58. Observation.component:SystolicBP.code.coding:SBPCode
            Slice NameSBPCode
            Definition

            Systolic Blood Pressure.


            A reference to a code defined by a terminology system.

            ShortSystolic Blood PressureCode defined by a terminology system
            Comments

            Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

            Control10..1*
            TypeCoding
            Is Modifierfalse
            Summarytrue
            Requirements

            Allows for alternative encodings within a code system, and translations to other code systems.

            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            60. Observation.component:SystolicBP.code.coding:SBPCode.system
            Definition

            The identification of the code system that defines the meaning of the symbol in the code.

            ShortIdentity of the terminology system
            Comments

            The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.

            Control10..1
            Typeuri
            Is Modifierfalse
            Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
            Summarytrue
            Requirements

            Need to be unambiguous about the source of the definition of the symbol.

            Fixed Valuehttp://loinc.org
            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            62. Observation.component:SystolicBP.code.coding:SBPCode.code
            Definition

            A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

            ShortSymbol in syntax defined by the system
            Control10..1
            Typecode
            Is Modifierfalse
            Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
            Summarytrue
            Requirements

            Need to refer to a particular code in the system.

            Fixed Value8480-6
            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            64. Observation.component:SystolicBP.value[x]
            Definition

            Vital Sign Value recorded with UCUM.


            The information determined as a result of making the observation, if the information has a simple value.

            ShortVital Sign Value recorded with UCUMActual component result
            Comments

            Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


            Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

            Control0..1
            This element is affected by the following invariants: vs-3
            BindingUnless not suitable, these codes SHALL be taken from For codes, see VitalSignsUnits
            (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

            Common UCUM units for recording Vital Signs.

            TypeQuantity, dateTime, boolean, string, SampledData, Period, Ratio, integer, time, Range, CodeableConcept
            [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
            Is Modifierfalse
            Must Supporttrue
            Summarytrue
            Requirements
            1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

            An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

            Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
            SlicingThis element introduces a set of slices on Observation.component.value[x]. The slices areUnordered and Open, and can be differentiated using the following discriminators:
            • type @ $this
            • 66. Observation.component:SystolicBP.value[x].value
              Definition

              The value of the measured amount. The value includes an implicit precision in the presentation of the value.

              ShortNumerical value (with implicit precision)
              Comments

              The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

              Control10..1
              Typedecimal
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Must Supporttrue
              Summarytrue
              Requirements

              Precision is handled implicitly in almost all cases of measurement.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              68. Observation.component:SystolicBP.value[x].comparator
              Definition

              How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

              Short< | <= | >= | > - how to understand the value
              Control0..1
              BindingThe codes SHALL be taken from QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
              (required to http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1)

              How the Quantity should be understood and represented.

              Typecode
              Is Modifiertrue because This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Summarytrue
              Requirements

              Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

              Meaning if MissingIf there is no comparator, then there is no modification of the value
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              70. Observation.component:SystolicBP.value[x].unit
              Definition

              A human-readable form of the unit.

              ShortUnit representation
              Control10..1
              Typestring
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Must Supporttrue
              Summarytrue
              Requirements

              There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              72. Observation.component:SystolicBP.value[x].system
              Definition

              The identification of the system that provides the coded form of the unit.

              ShortSystem that defines coded unit form
              Control10..1
              This element is affected by the following invariants: qty-3
              Typeuri
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Must Supporttrue
              Summarytrue
              Requirements

              Need to know the system that defines the coded form of the unit.

              Fixed Valuehttp://unitsofmeasure.org
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              74. Observation.component:SystolicBP.value[x].code
              Definition

              Coded responses from the common UCUM units for vital signs value set.


              A computer processable form of the unit in some unit representation system.

              ShortCoded responses from the common UCUM units for vital signs value set.Coded form of the unit
              Comments

              The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

              Control10..1
              Typecode
              Is Modifierfalse
              Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
              Must Supporttrue
              Summarytrue
              Requirements

              Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

              Fixed Valuemm[Hg]
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              76. Observation.component:SystolicBP.dataAbsentReason
              Definition

              Provides a reason why the expected value in the element Observation.component.value[x] is missing.

              ShortWhy the component result is missing
              Comments

              "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

              The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

              Control0..1
              This element is affected by the following invariants: obs-6, vs-3
              BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
              (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

              Codes specifying why the result (Observation.value[x]) is missing.

              TypeCodeableConcept
              Is Modifierfalse
              Must Supporttrue
              Summaryfalse
              Requirements

              For many results it is necessary to handle exceptional values in measurements.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              78. Observation.component:DiastolicBP
              Slice NameDiastolicBP
              Definition

              Used when reporting diastolic blood pressure.


              Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

              ShortUsed when reporting diastolic blood pressure.Component results
              Comments

              For a discussion on the ways Observations can be assembled in groups together see Notes below.


              For a discussion on the ways Observations can be assembled in groups together see Notes below.

              Control10..1*
              TypeBackboneElement
              Is Modifierfalse
              Must Supporttrue
              Summarytrue
              Requirements

              Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
              80. Observation.component:DiastolicBP.modifierExtension
              Definition

              May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

              Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

              ShortExtensions that cannot be ignored even if unrecognized
              Comments

              There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

              Control0..*
              TypeExtension
              Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
              Summarytrue
              Requirements

              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


              Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

              Alternate Namesextensions, user content, modifiers
              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
              82. Observation.component:DiastolicBP.code
              Definition

              Describes what was observed. Sometimes this is called the observation "code".

              ShortType of component observation (code / type)
              Comments

              additional codes that translate or map to this code are allowed. For example a more granular LOINC code or code that is used locally in a system.


              All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

              Control1..1
              BindingUnless not suitable, these codes SHALL be taken from For example codes, see VitalSignshttp://hl7.org/fhir/ValueSet/observation-codes
              (extensible to http://hl7.org/fhir/ValueSet/observation-vitalsignresult)

              This identifies the vital sign result type.


              Codes identifying names of simple observations.

              TypeCodeableConcept
              Is Modifierfalse
              Must Supporttrue
              Summarytrue
              Requirements

              Knowing what kind of observation is being made is essential to understanding the observation.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              84. Observation.component:DiastolicBP.code.coding
              Definition

              Diastolic Blood Pressure.


              A reference to a code defined by a terminology system.

              ShortDiastolic Blood PressureCode defined by a terminology system
              Comments

              Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

              Control10..*
              TypeCoding
              Is Modifierfalse
              Summarytrue
              Requirements

              Allows for alternative encodings within a code system, and translations to other code systems.

              Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
              SlicingThis element introduces a set of slices on Observation.component.code.coding. The slices areUnordered and Open, and can be differentiated using the following discriminators:
              • value @ code
              • value @ system
              • 86. Observation.component:DiastolicBP.code.coding:DBPCode
                Slice NameDBPCode
                Definition

                Diastolic Blood Pressure.


                A reference to a code defined by a terminology system.

                ShortDiastolic Blood PressureCode defined by a terminology system
                Comments

                Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

                Control10..1*
                TypeCoding
                Is Modifierfalse
                Summarytrue
                Requirements

                Allows for alternative encodings within a code system, and translations to other code systems.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                88. Observation.component:DiastolicBP.code.coding:DBPCode.system
                Definition

                The identification of the code system that defines the meaning of the symbol in the code.

                ShortIdentity of the terminology system
                Comments

                The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.

                Control10..1
                Typeuri
                Is Modifierfalse
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Summarytrue
                Requirements

                Need to be unambiguous about the source of the definition of the symbol.

                Fixed Valuehttp://loinc.org
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                90. Observation.component:DiastolicBP.code.coding:DBPCode.code
                Definition

                A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

                ShortSymbol in syntax defined by the system
                Control10..1
                Typecode
                Is Modifierfalse
                Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                Summarytrue
                Requirements

                Need to refer to a particular code in the system.

                Fixed Value8462-4
                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                92. Observation.component:DiastolicBP.value[x]
                Definition

                Vital Sign Value recorded with UCUM.


                The information determined as a result of making the observation, if the information has a simple value.

                ShortVital Sign Value recorded with UCUMActual component result
                Comments

                Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


                Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

                Control0..1
                This element is affected by the following invariants: vs-3
                BindingUnless not suitable, these codes SHALL be taken from For codes, see VitalSignsUnits
                (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

                Common UCUM units for recording Vital Signs.

                TypeQuantity, dateTime, boolean, string, SampledData, Period, Ratio, integer, time, Range, CodeableConcept
                [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
                Is Modifierfalse
                Must Supporttrue
                Summarytrue
                Requirements
                1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

                An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                SlicingThis element introduces a set of slices on Observation.component.value[x]. The slices areUnordered and Open, and can be differentiated using the following discriminators:
                • type @ $this
                • 94. Observation.component:DiastolicBP.value[x].value
                  Definition

                  The value of the measured amount. The value includes an implicit precision in the presentation of the value.

                  ShortNumerical value (with implicit precision)
                  Comments

                  The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).

                  Control10..1
                  Typedecimal
                  Is Modifierfalse
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Precision is handled implicitly in almost all cases of measurement.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  96. Observation.component:DiastolicBP.value[x].comparator
                  Definition

                  How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value.

                  Short< | <= | >= | > - how to understand the value
                  Control0..1
                  BindingThe codes SHALL be taken from QuantityComparatorhttp://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1
                  (required to http://hl7.org/fhir/ValueSet/quantity-comparator|4.0.1)

                  How the Quantity should be understood and represented.

                  Typecode
                  Is Modifiertrue because This is labeled as "Is Modifier" because the comparator modifies the interpretation of the value significantly. If there is no comparator, then there is no modification of the value
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Summarytrue
                  Requirements

                  Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology.

                  Meaning if MissingIf there is no comparator, then there is no modification of the value
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  98. Observation.component:DiastolicBP.value[x].unit
                  Definition

                  A human-readable form of the unit.

                  ShortUnit representation
                  Control10..1
                  Typestring
                  Is Modifierfalse
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  100. Observation.component:DiastolicBP.value[x].system
                  Definition

                  The identification of the system that provides the coded form of the unit.

                  ShortSystem that defines coded unit form
                  Control10..1
                  This element is affected by the following invariants: qty-3
                  Typeuri
                  Is Modifierfalse
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Need to know the system that defines the coded form of the unit.

                  Fixed Valuehttp://unitsofmeasure.org
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  102. Observation.component:DiastolicBP.value[x].code
                  Definition

                  Coded responses from the common UCUM units for vital signs value set.


                  A computer processable form of the unit in some unit representation system.

                  ShortCoded responses from the common UCUM units for vital signs value set.Coded form of the unit
                  Comments

                  The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.

                  Control10..1
                  Typecode
                  Is Modifierfalse
                  Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest.

                  Fixed Valuemm[Hg]
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  104. Observation.component:DiastolicBP.dataAbsentReason
                  Definition

                  Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                  ShortWhy the component result is missing
                  Comments

                  "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                  The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                  Control0..1
                  This element is affected by the following invariants: obs-6, vs-3
                  BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
                  (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

                  Codes specifying why the result (Observation.value[x]) is missing.

                  TypeCodeableConcept
                  Is Modifierfalse
                  Must Supporttrue
                  Summaryfalse
                  Requirements

                  For many results it is necessary to handle exceptional values in measurements.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  106. Observation.component:MeanBP
                  Slice NameMeanBP
                  Definition

                  Mean blood pressure


                  Some observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations.

                  ShortMean blood pressureComponent results
                  Comments

                  For a discussion on the ways Observations can be assembled in groups together see Notes below.


                  For a discussion on the ways Observations can be assembled in groups together see Notes below.

                  Control0..1*
                  TypeBackboneElement
                  Is Modifierfalse
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  vs-3: If there is no a value a data absent reason must be present (value.exists() or dataAbsentReason.exists())
                  108. Observation.component:MeanBP.modifierExtension
                  Definition

                  May be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions.

                  Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself).

                  ShortExtensions that cannot be ignored even if unrecognized
                  Comments

                  There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

                  Control0..*
                  TypeExtension
                  Is Modifiertrue because Modifier extensions are expected to modify the meaning or interpretation of the element that contains them
                  Summarytrue
                  Requirements

                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.


                  Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions.

                  Alternate Namesextensions, user content, modifiers
                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  ext-1: Must have either extensions or value[x], not both (extension.exists() != value.exists())
                  110. Observation.component:MeanBP.code
                  Definition

                  Describes what was observed. Sometimes this is called the observation "code".

                  ShortType of component observation (code / type)
                  Comments

                  All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation.

                  Control1..1
                  BindingUnless not suitable, these codes SHALL be taken from For example codes, see VitalSignshttp://hl7.org/fhir/ValueSet/observation-codes
                  (extensible to http://hl7.org/fhir/ValueSet/observation-vitalsignresult)

                  This identifies the vital sign result type.


                  Codes identifying names of simple observations.

                  TypeCodeableConcept
                  Is Modifierfalse
                  Must Supporttrue
                  Summarytrue
                  Requirements

                  Knowing what kind of observation is being made is essential to understanding the observation.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  112. Observation.component:MeanBP.code.coding
                  Definition

                  A reference to a code defined by a terminology system.

                  ShortCode defined by a terminology system
                  Comments

                  Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

                  Control10..*
                  TypeCoding
                  Is Modifierfalse
                  Summarytrue
                  Requirements

                  Allows for alternative encodings within a code system, and translations to other code systems.

                  Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                  SlicingThis element introduces a set of slices on Observation.component.code.coding. The slices areUnordered and Open, and can be differentiated using the following discriminators:
                  • value @ code
                  • value @ system
                  • 114. Observation.component:MeanBP.code.coding:MBPCode
                    Slice NameMBPCode
                    Definition

                    A reference to a code defined by a terminology system.

                    ShortCode defined by a terminology system
                    Comments

                    Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.

                    Control10..1*
                    TypeCoding
                    Is Modifierfalse
                    Summarytrue
                    Requirements

                    Allows for alternative encodings within a code system, and translations to other code systems.

                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    116. Observation.component:MeanBP.code.coding:MBPCode.system
                    Definition

                    The identification of the code system that defines the meaning of the symbol in the code.

                    ShortIdentity of the terminology system
                    Comments

                    The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.

                    Control10..1
                    Typeuri
                    Is Modifierfalse
                    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                    Summarytrue
                    Requirements

                    Need to be unambiguous about the source of the definition of the symbol.

                    Fixed Valuehttp://loinc.org
                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    118. Observation.component:MeanBP.code.coding:MBPCode.code
                    Definition

                    Mean blood pressure


                    A symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination).

                    ShortMean blood pressureSymbol in syntax defined by the system
                    Control10..1
                    Typecode
                    Is Modifierfalse
                    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                    Summarytrue
                    Requirements

                    Need to refer to a particular code in the system.

                    Fixed Value8478-0
                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    120. Observation.component:MeanBP.value[x]
                    Definition

                    Vital Sign Value recorded with UCUM.


                    The information determined as a result of making the observation, if the information has a simple value.

                    ShortVital Sign Value recorded with UCUMActual component result
                    Comments

                    Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.


                    Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.

                    Control0..1
                    This element is affected by the following invariants: vs-3
                    BindingUnless not suitable, these codes SHALL be taken from For codes, see VitalSignsUnits
                    (extensible to http://hl7.org/fhir/ValueSet/ucum-vitals-common|4.0.1)

                    Common UCUM units for recording Vital Signs.

                    TypeChoice of: Quantity, CodeableConcept, string, boolean, integer, Range, Ratio, SampledData, time, dateTime, Period
                    [x] NoteSeeChoice of Data Typesfor further information about how to use [x]
                    Is Modifierfalse
                    Primitive ValueThis primitive element may be present, or absent, or replaced by an extension
                    Must Supporttrue
                    Must Support TypesNo must-support rules about the choice of types/profiles
                    Summarytrue
                    Requirements
                    1. SHALL contain exactly one [1..1] value with @xsi:type="PQ" (CONF:7305).

                    An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations.

                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))
                    122. Observation.component:MeanBP.dataAbsentReason
                    Definition

                    Provides a reason why the expected value in the element Observation.component.value[x] is missing.

                    ShortWhy the component result is missing
                    Comments

                    "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done".

                    The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values.

                    Control0..1
                    This element is affected by the following invariants: obs-6, vs-3
                    BindingUnless not suitable, these codes SHALL be taken from DataAbsentReasonhttp://hl7.org/fhir/ValueSet/data-absent-reason
                    (extensible to http://hl7.org/fhir/ValueSet/data-absent-reason)

                    Codes specifying why the result (Observation.value[x]) is missing.

                    TypeCodeableConcept
                    Is Modifierfalse
                    Must Supporttrue
                    Summaryfalse
                    Requirements

                    For many results it is necessary to handle exceptional values in measurements.

                    Invariantsele-1: All FHIR elements must have a @value or children (hasValue() or (children().count() > id.count()))